Goodman Furnace: Leaking water
Applies to: 90%+ AFUE condensing Goodman furnaces (nameplate AFUE 90 or higher, two PVC pipes) with a condensate drain system; 80% AFUE models leak only from an attached AC coil.
Typical repair cost: $0 DIY – $1,800+ if the secondary heat exchanger is replaced — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Goodman furnace leaking water: what it means

“Leaking water” is not a flash-code on Goodman furnaces — it is a physical symptom, so your control board may show no fault at all, or it may show a pressure switch code (2 or 3 flashes) as a downstream effect of water backing up.

Flash-code meanings differ between Goodman/Amana control board generations, and some newer boards use a 7-segment display or a different sequence — always confirm what your flashes mean against the diagnostic label printed on the inside of the blower-door panel for your specific board.

Water at a Goodman furnace almost always comes from one of three systems:

  1. The condensate drain system on high-efficiency (90%+ AFUE) condensing furnaces, which by design produce several gallons of acidic water per day of runtime.
  2. The evaporator (AC) coil and drain pan sitting on top of the furnace, which leaks in cooling season and drips down onto the furnace cabinet.
  3. A cracked secondary heat exchanger on a condensing furnace, which lets condensate escape where it shouldn’t.

If you have an 80% AFUE (non-condensing) Goodman furnace, it has no condensate drain — so water there is almost certainly from the AC coil above it, not the furnace itself.

This is rated pro because distinguishing a simple clogged drain from a cracked heat exchanger, and safely drying out electrical components, is technician work.

Goodman furnace leaking water: common causes, ranked by probability

  1. Clogged condensate drain line or trap. Algae, dust, and mineral sludge block the drain, so condensate backs up and overflows from the collector box or trap. This is by far the most common cause on condensing Goodman furnaces.
  2. Clogged or overflowing AC condensate drain (cooling season). The evaporator coil above the furnace overflows and drips onto the cabinet. Common when the furnace only “leaks” while the AC runs.
  3. Cracked or loose condensate trap / disconnected drain hose. Goodman traps and rubber hoses can crack, split, or work loose, dumping water at the base of the furnace.
  4. Blocked or sagging flue/vent condensate. Improper PVC pitch lets condensate pool and drain back into the furnace instead of out.
  5. Clogged or dirty inducer / collector box drain port. Water can’t clear the collector box and overflows, sometimes tripping the pressure switch.
  6. Condensate pump failure (where installed in basements below the drain). A failed pump lets its reservoir overflow.
  7. Cracked secondary heat exchanger. Least common but most serious — condensate escapes internally and leaks from the cabinet. Requires professional inspection and often replacement. Because this is a gas appliance, a cracked heat exchanger can also allow combustion gases, including carbon monoxide, to escape: shut the furnace off and do not run it again until a technician has inspected it, and make sure you have working CO alarms on every level of the home. If a CO alarm sounds, or anyone has headaches, nausea, dizziness, or flu-like symptoms that improve when they leave the house, get everyone outside and call 911 or your gas utility from outside.

How to fix Goodman furnace leaking water: safe checks first

Turn the furnace off at its dedicated wall switch before touching anything wet.

Do not open the furnace cabinet, remove the trap, or probe the collector box — that’s technician work.

How a technician will diagnose it

A good tech shows you the actual leak source before quoting a repair — insist on that before approving heat-exchanger-level work.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Water pooling at base during heatingClogged condensate line/trapTurn off, vac up water, check for a slipped hose outside the cabinetRemove & flush trap, clear collector box
Leaks only when AC runsAC coil/drain pan overflowReplace filter, clear floor drainClear AC drain, level pan, check coil
Water plus 2 or 3 flash codeCondensate backup tripping pressure switch (confirm code on blower-door label)Turn off, dry board areaClear drain, test pressure switch & tubing
Steady drip from a cracked hose/trapSplit trap or loose fittingReseat a slipped hose only if it’s outside the cabinetReplace trap/hoses
Condensate pump reservoir overflowingFailed or unplugged pumpConfirm power, reset onceReplace condensate pump
Water inside cabinet, no clear drain issueCracked secondary heat exchangerShut furnace off and leave it off, call pro, check CO alarms; leave the house and call 911/gas utility if an alarm sounds or anyone feels illInspect & replace heat exchanger

Goodman furnace leaking water repair cost

RepairTypical US cost
DIY drain line clearing (brush/tablets, shop vac)$0 – $40
Professional condensate drain clearing / flush$100 – $250
Condensate trap or drain hose replacement$150 – $350
Collector box cleaning or replacement$250 – $600
Condensate pump replacement$150 – $350
AC drain pan / coil drain service$150 – $450
Secondary heat exchanger replacement$600 – $1,800 (often near economical repair limit on older units)

Prices vary by region and access. If a cracked heat exchanger is confirmed on an older furnace, weigh repair against a full replacement.

Flash-code meanings vary by control board generation — check the diagnostic label inside the blower door before matching your furnace to any of these.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Is a leaking Goodman furnace dangerous?

Water alone is usually not dangerous, but it can short out the control board, rust the heat exchanger area, and cause pressure switch faults. On a condensing furnace, a cracked heat exchanger leak needs immediate professional attention: do not run the furnace until it has been inspected, and make sure you have working carbon monoxide alarms. If anyone in the home has headaches, nausea, or dizziness, or a CO alarm sounds, leave the house and call 911 or your gas utility from outside.

Why does my high-efficiency Goodman furnace leak water but my old one never did?

Condensing (90%+ AFUE) furnaces extract heat until the flue gas condenses into water, which must drain away. That condensate system is the number-one leak source. Older 80% furnaces vent that moisture out the flue as gas.

Can I just keep running the furnace while it leaks?

No. Water pooling near the control board or inducer can cause electrical failure and safety lockouts. Turn the furnace off at the switch, soak up the water, and address the drain before running it again. If a cracked heat exchanger is suspected, leave the furnace off until a technician has inspected it and confirm your CO alarms are working.