Rheem · Air Conditioner

Rheem AC Not Cooling: Causes, Fixes & Repair Costs

Last updated Oct 25, 2026 · By fixme.vip Editorial

Rheem Air Conditioner: Not cooling
Applies to: Rheem and Ruud split-system central air conditioners, including Classic, Classic Plus and Prestige series (RA13, RA14, RA16, RA17, RA20 and similar). Single-stage units have no outdoor diagnostic display. Many two-stage and variable-speed (EcoNet) models show flash codes on the outdoor control board. Exact codes and lockout behavior vary by model and board.
Typical repair cost: $0 DIY – $3,500+ if the compressor or coil must be replaced — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Rheem air conditioner not cooling: what it means

“Not cooling” is a symptom, not a stored fault code. It means the system is running, or trying to run, without lowering the indoor temperature. Most Rheem single-stage condensers have no diagnostic display, so the cause has to be traced by symptom.

Some two-stage and variable-speed Rheem models report faults as LED flash codes on the outdoor control board or on an EcoNet thermostat. Examples include high or low pressure lockouts and compressor protection trips.

On units with lockout logic, the behavior varies by board:

Check the label inside your outdoor unit’s service panel, or the installation manual, for your model’s exact behavior.

This page covers central air conditioners. If you have a heat pump, see the separate heat pump not-cooling page.

Rheem air conditioner not cooling: common causes, ranked by probability

  1. Dirty air filter or blocked airflow. Restricted airflow drops cooling capacity and can freeze the indoor coil. This is the most common cause and the cheapest fix.
  2. Thermostat settings or power. Causes include a thermostat set to Heat or Fan only, dead batteries, or a setpoint above room temperature.
  3. Tripped breaker or outdoor disconnect. The indoor blower runs on a separate circuit, so the house moves air but nothing cools it.
  4. Failed run capacitor. This is the most common electrical failure on Rheem condensers. The compressor or fan hums but won’t start, or runs and overheats.
  5. Failed or pitted contactor. The outdoor unit won’t engage even though the thermostat is calling for cooling.
  6. Frozen evaporator coil. It usually results from low airflow or low refrigerant. Airflow stops and ice may be visible on the refrigerant lines.
  7. Refrigerant leak. Rheem evaporator coils, like many brands’ coils, have had documented formicary corrosion leaks. On models with pressure switches, a leak may trigger a low-pressure lockout.
  8. Dirty outdoor condenser coil. It causes high head pressure, poor cooling and possible high-pressure trips on hot days.
  9. Condensate overflow safety switch tripped. A clogged drain trips a float switch that shuts off cooling.
  10. Outdoor fan motor failure. The compressor runs but overheats and cycles off on internal overload.
  11. Compressor failure. This is the least common cause but the most expensive one, and it is usually confirmed only after the items above are ruled out.

How to fix Rheem air conditioner not cooling: safe checks first

Do not open the condenser’s electrical panel, touch capacitors (they hold a charge even with power off), or attempt any refrigerant work.

How a technician will diagnose it

A competent tech will typically:

  1. Confirm the call. They verify 24V at the outdoor contactor coil and confirm the thermostat is calling for cooling.
  2. Test line voltage at the disconnect and contactor, and inspect the contactor points for pitting.
  3. Test the run capacitor with a meter in microfarads (µF). They compare the reading against its rating, usually within ±6%.
  4. Measure amperage on the compressor and fan motor and compare it against the nameplate.
  5. Attach gauges or digital probes. They check suction and liquid pressures, superheat (fixed-orifice systems) or subcooling (TXV systems, common on Rheem). These are compared to the charging chart on the unit.
  6. Measure temperature split across the indoor coil. A normal split is roughly 15–20°F.
  7. Check airflow: static pressure, blower speed and filter, and evaporator coil cleanliness.
  8. Read board flash codes on two-stage or variable-speed models, if equipped.
  9. Leak-search with an electronic detector, bubbles or a nitrogen pressure test if the charge is low.

Red flags in a quote:

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Nothing runs indoors or outThermostat, batteries, breakerCheck settings, replace batteries, reset breaker onceLow-voltage wiring, transformer, fuse on control board
Indoor fan runs, outdoor unit silentOutdoor breaker or disconnect, contactor, capacitorCheck outdoor breaker and disconnectTest and replace contactor or capacitor
Outdoor unit hums, fan doesn’t spinFailed capacitor or fan motorTurn off power at the disconnect, then callReplace capacitor or fan motor
Ice on lines or indoor coilDirty filter, low airflow, low refrigerantReplace filter, run fan only to thaw, open ventsCheck charge, leak search, blower check
Runs constantly, air only slightly coolLow refrigerant, dirty coilsReplace filter, rinse outdoor coilLeak search, coil cleaning, charge correction
Cooling stops, water near indoor unitClogged condensate, tripped float switchClear condensate lineClear trap, replace pump or switch
Works mornings, quits on hot afternoonsDirty condenser, weak capacitor, high-pressure tripClear debris, rinse coilTest capacitor, check pressures and fan
Outdoor board flashing a code (some models)Pressure or compressor protection lockoutOne power-cycle resetInterpret code, fix root cause
Breaker trips when compressor startsShorted or grounded compressor, bad capacitorDo not keep resettingCompressor winding tests, hard-start kit or replacement

Rheem air conditioner not cooling repair cost

Typical US prices, including parts and labor, in 2026:

RepairTypical costNotes
Air filter$10 – $40DIY
Thermostat replacement$30 DIY – $350 installedSmart or EcoNet models cost more
Service call / diagnostic$90 – $200Often credited toward the repair
Run capacitor$120 – $350Part is cheap; most of the cost is labor and trip charge
Contactor$150 – $350
Condensate drain clearing / float switch$100 – $250
Outdoor fan motor$350 – $800
Condenser coil cleaning$100 – $250
Leak search$200 – $500
Refrigerant recharge (R-410A)$200 – $700Price depends on pounds needed
Refrigerant recharge (R-454B, on 2025+ units)$250 – $800
Minor leak repair (Schrader core, braze joint)$200 – $600Plus recharge
Evaporator coil replacement$1,200 – $2,800Parts often under warranty; labor not
Compressor replacement$1,800 – $3,500+Part often under warranty; labor and refrigerant extra

If the system is more than 12–15 years old and needs a compressor or coil, get a quote for replacing the whole system before you commit to the repair.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why is my Rheem AC running but blowing warm air?

If the indoor blower runs but the air is warm, the outdoor unit is usually not doing its job. Common causes are a failed capacitor, a stuck or burned contactor, a tripped outdoor breaker or a refrigerant leak. Go outside and check whether the outdoor fan and compressor are running.

My Rheem AC coil is frozen. What should I do?

Set the thermostat to Off and the fan to On so the ice melts. This can take several hours. Replace a dirty filter and open any closed registers. If the coil freezes again, a technician should check the refrigerant charge and blower operation.

Can I add refrigerant to my Rheem AC myself?

No. Refrigerant work requires EPA Section 608 certification. A low charge also means there is a leak, and topping it off without finding the leak only delays the problem. A technician should locate and repair the leak before recharging.

Does Rheem's warranty cover a not-cooling repair?

Rheem's limited warranty usually covers parts such as compressors, coils and capacitors for 10 years on registered units, often 5 years if unregistered. Labor and refrigerant are typically not covered unless you bought an extended labor plan. Check your registration and warranty certificate.

How long should my Rheem AC take to cool the house?

A properly sized, working system typically cools the air leaving the registers 15–20°F below the room air. It should lower the indoor temperature about 1–2°F per hour on hot days. If it never catches up when it is under 95°F outside, have it checked.

Different code on your air conditioner? Look it up — and if we haven't covered it yet, telling us is how it gets written next.