Rheem · Heat Pump

Rheem Heat Pump Not Heating: Causes, Fixes & Costs

Last updated Oct 5, 2026 · By fixme.vip Editorial

Rheem Heat Pump: Not heating
Applies to: Rheem and Ruud split heat pumps, including Classic, Classic Plus and Prestige series with single-stage, two-stage or variable-speed outdoor units. Fault reporting varies by control board. Older models use a defrost board with limited LED codes. Newer EcoNet and communicating models show alerts on the thermostat or outdoor-board display. Air-handler and auxiliary-heat wiring also varies by installation.
Typical repair cost: $0 DIY – $2,500+ if a reversing valve or compressor must be replaced — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Rheem heat pump not heating: what it means

“Not heating” is a symptom, not a numbered Rheem fault code. It means the heat pump is either not running in heat mode or running without delivering warm air.

A Rheem heat pump heats by reversing its refrigerant flow. A reversing valve, controlled by the thermostat’s O (or B) signal, makes the outdoor coil absorb heat and the indoor coil release it. When that process fails, the house stays cold. Typical failures include:

If your unit is also flashing a fault light, or is iced over and not defrosting, see those dedicated pages first. This page covers heat pumps that are not frozen and show no clear fault code, but still produce no meaningful heat.

How the system reports problems depends on the model. Older Rheem and Ruud defrost boards give little or no feedback. EcoNet and communicating systems show specific alerts on the thermostat, which a technician can use to narrow the cause quickly.

Rheem heat pump not heating: common causes, ranked by probability

  1. Thermostat setting or configuration. The thermostat may be set to Cool or Off, or the setpoint may be below room temperature. A newly installed thermostat may also have the wrong reversing-valve setting (O vs. B). Rheem heat pumps energize the reversing valve in cooling (O). A thermostat set to B runs cooling when you call for heat.
  2. Dirty air filter or blocked airflow. Restricted airflow cuts heat delivery. It can also trip high-pressure protection in heat mode, because the indoor coil acts as the condenser.
  3. Outdoor unit not running (power or electrical). Possible causes include:
    • A tripped breaker or outdoor disconnect
    • A failed run capacitor
    • A burned or pitted contactor
    • A control-board lockout
  4. Reversing valve or solenoid failure. The valve is stuck in cooling position, or the solenoid coil has failed. The outdoor unit runs, but the house gets cool air.
  5. Low refrigerant charge (leak). The system runs long and produces lukewarm air, sometimes with frosting patterns that don’t match normal defrost.
  6. Auxiliary or emergency heat failure. Below the balance point, the heat pump alone can’t keep up. Common culprits are failed heat strips, sequencers, limits, or auxiliary-heat wiring in the air handler. The house falls behind in cold weather even though the heat pump works.
  7. Compressor failure. The fan runs but the compressor won’t start, or it hums and trips on overload. This is less common, and it’s diagnosed only after the capacitor, contactor and controls check out.
  8. Undersized system or ductwork leaks. These cause chronic underperformance rather than a sudden failure. Typical signs are leaky ducts in an attic or crawlspace, or a unit too small for the home.

How to fix Rheem heat pump not heating: safe checks first

How a technician will diagnose it

A competent tech will typically work through these steps:

  1. Verify the call for heat. They confirm the thermostat is sending Y (compressor) and the correct O/B signal. On EcoNet or communicating systems, they read stored alerts and fault history.
  2. Check outdoor unit power and controls. This includes:
    • Line voltage at the disconnect
    • 24V control voltage at the contactor
    • Whether the contactor pulls in
    • Defrost or control-board LED status and any lockout history
  3. Test the capacitor and compressor. They measure capacitance against the rating and check compressor windings and amp draw.
  4. Test the reversing valve. They measure line temperatures across the valve and check voltage and resistance at the solenoid coil. They also observe whether the valve shifts when the thermostat switches between Heat and Cool.
  5. Check the refrigerant charge. Using gauges or digital probes, they measure pressures, superheat and subcooling against Rheem’s heating charging chart. If the charge is low, they should leak-search before adding refrigerant. Topping off without finding the leak is a red flag.
  6. Check auxiliary heat. They measure amp draw on each heat strip and test sequencers, relays and limits.
  7. Measure airflow and temperature rise. They check static pressure and the supply-to-return temperature difference.

Sanity check on quotes: Be wary of a reversing-valve or compressor diagnosis given without electrical tests and pressure readings. The same goes for refrigerant added with no mention of a leak.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Nothing runs, thermostat blankDead batteries or no powerReplace batteries; check breakers onceCheck transformer, fuse, low-voltage wiring
Air blows cool, outdoor unit runningThermostat on Cool, wrong O/B setting, or stuck reversing valveConfirm Heat modeCorrect O/B setup; test solenoid; replace valve
Indoor fan runs, outdoor unit silentTripped breaker, bad contactor or capacitor, board lockoutReset breaker once; one power-cycle resetTest and replace capacitor or contactor; diagnose lockout
Outdoor fan runs, compressor hums or is silentFailed capacitor or compressor problemNone beyond one resetTest capacitor and windings; replace parts or compressor
Lukewarm air, very long run timesLow refrigerant or dirty filterReplace filterLeak search, repair, recharge per Rheem chart
Fine in mild weather, cold below freezingAuxiliary heat strips or sequencer failedTest Emergency Heat; check aux heat breakerTest and replace heat strips, sequencer, limits
Weak airflow at all registersClogged filter or blower issueReplace filter; open registersCheck blower motor, coil, static pressure
System stops, water near air handlerCondensate float switch trippedClear visible drain lineClear trap, check pan and switch

Rheem heat pump not heating repair cost

Typical US installed prices, parts plus labor. Prices vary by region and warranty status. Rheem parts warranties often cover components, but not labor.

RepairTypical cost
Filter replacement$10–$50 (DIY)
Thermostat batteries$5–$10 (DIY)
New heat pump thermostat$40–$250 DIY, $150–$450 installed
Service call / diagnostic$90–$250
Run capacitor$150–$400
Contactor$150–$350
Reversing valve solenoid coil$150–$400
Defrost or control board$300–$800
Heat strip / sequencer repair$200–$700
Refrigerant leak search and repair, plus recharge$400–$1,500+, depending on leak location and refrigerant type
Reversing valve replacement$900–$2,500 (brazing, evacuation, recharge)
Compressor replacement$1,800–$4,000+; often weighed against a new outdoor unit
Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why is my Rheem heat pump running but blowing cool air?

Heat pump supply air often runs around 90–100°F, which can feel cool on your hand, especially in cold weather. If the air is truly at room temperature or colder, the cause could be a thermostat set to Cool, a stuck reversing valve, low refrigerant, or an outdoor unit that isn't running.

Is it normal for a Rheem heat pump to struggle when it's very cold outside?

Yes. Output drops as outdoor temperatures fall, and most systems rely on auxiliary electric heat strips or a furnace below a balance point, often in the 25–35°F range. If the house won't stay warm in mild weather, or the auxiliary heat never engages, something is wrong.

Can I reset my Rheem heat pump myself?

You can turn the system off at the thermostat, switch off the outdoor and indoor breakers for about five minutes, then restore power once. If it still doesn't heat, or a fault reappears, stop and call a technician. Repeated resets can damage the compressor.

Does the not-heating problem clear on its own?

Not heating isn't a single fault code, so there's no defined auto-reset. Some protective lockouts on Rheem outdoor boards, such as pressure-switch or compressor-protection lockouts, clear after a timed delay or a power cycle, depending on the board. Persistent problems need diagnosis.

How much does it cost to fix a Rheem heat pump that won't heat?

Simple fixes like a filter or thermostat setting cost little or nothing. Capacitors and contactors usually run $150–$400 installed. Reversing valves and refrigerant leak repairs often cost $800–$2,500. Compressor replacement can approach the cost of a new outdoor unit.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.