Goodman Heat Pump Breaker Keeps Tripping: Causes & Costs

Last updated Oct 12, 2026 · By fixme.vip Editorial

Goodman Heat Pump: Breaker keeps tripping
Applies to: Goodman single-stage and two-stage split-system heat pumps that use a capacitor-run (PSC) compressor and a contactor (GSZ, GSZB, non-inverter GSZC/DSZC and older SSZ/CPLE series) with matching air handlers (ARUF, AVPTC, MBVC, ASPT). Inverter-driven variable-speed models have no compressor run capacitor or conventional contactor and use a different cause list and diagnosis. Diagnosis also differs depending on whether the outdoor-unit breaker or the air-handler/heat-strip breaker is tripping. Communicating models (ComfortBridge or ComfortNet) may also log fault codes that help narrow the cause.
Typical repair cost: $0 if a one-time nuisance trip – $120-$350 for capacitor, contactor or breaker – $2,000+ if the compressor is shorted — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Goodman heat pump breaker keeps tripping: what it means

“Breaker keeps tripping” is not a Goodman diagnostic code. It is a symptom. The circuit breaker feeding your heat pump or its air handler is sensing more current than it is rated for, or a short to ground, and cutting power to protect the wiring.

Goodman split systems normally have two power supplies:

The breaker stays off until someone resets it by hand. The fix depends on which breaker trips and when it trips:

Which units this page covers. The causes and diagnosis below are for single-stage and two-stage Goodman heat pumps with a capacitor-run compressor and a contactor. Inverter-driven variable-speed models are different. They drive the compressor through an inverter board and typically use an ECM fan, so they have no compressor run capacitor or conventional contactor. On those units, breaker trips point to the inverter drive, its components, or the ECM motor. The safe checks below still apply to them, but the cause ranking and technician steps do not.

Severity: pro. Everything beyond one breaker reset and basic airflow checks involves live 240V components and belongs to a licensed technician.

Goodman heat pump breaker keeps tripping: common causes, ranked by probability

These apply to capacitor-run single-stage and two-stage units. See the note above for inverter models.

  1. Failed or weak run capacitor (outdoor unit). Without proper capacitor assist, the compressor or fan motor draws high current trying to start. The single- and two-stage units covered here typically use a dual run capacitor for both the compressor and fan. This is the most common cause on units more than a few years old, especially after hot summers.
  2. Compressor hard-starting or locked rotor. A compressor that struggles to start pulls locked-rotor amps, often 5–7 times running current. On a locked rotor, the compressor’s internal overload often trips before the breaker does. When the breaker itself trips repeatedly on start, it usually means high locked-rotor draw combined with a weak capacitor, low supply voltage, or a marginal breaker. Causes of hard starting include worn compressor mechanics, low voltage, or pressures that haven’t equalized after a short-cycle.
  3. Loose, burnt, or corroded wiring or terminals. Heat and corrosion at the contactor, capacitor, disconnect or breaker lugs create resistance and arcing. Rodent damage to wiring is also common on outdoor units.
  4. Failing contactor. On units with a conventional contactor, pitted or welded contacts can chatter or cause arcing and uneven power delivery to the compressor.
  5. Shorted or seized condenser fan motor. A fan motor with a winding shorted to ground, or bearings that are seizing, overloads the circuit. The fan problem itself is covered separately (see Related codes).
  6. Grounded or shorted compressor winding. When compressor insulation breaks down, current flows to the casing. Breakers often trip instantly on reset. This is the most expensive cause.
  7. Electric heat strip or air-handler fault (indoor breaker). Possible faults include a shorted heater element, a failed sequencer or relay that energizes all strips at once, or a heat kit too large for its breaker or wire size. This often shows up only in cold weather when aux heat engages.
  8. Undersized or worn-out breaker. A breaker that has tripped many times, or one that is smaller than the unit’s rating plate calls for, can trip under normal load. An installer may have mismatched the breaker to the unit, which happens more often after equipment replacement.
  9. High head pressure from a dirty outdoor coil or restricted airflow. This raises compressor amp draw in cooling mode. It is usually a contributing factor rather than the sole cause.

How to fix Goodman heat pump breaker keeps tripping: safe checks first

Do not open the outdoor disconnect box, the unit’s service panel, or the air handler’s electrical compartment. These contain 240V and capacitors that hold a charge even with power off.

How a technician will diagnose it

On a capacitor-run single- or two-stage unit, a good tech will typically:

  1. Ask which breaker trips and when. Instant, on start, after a run, and heat-only trips point to different components.
  2. Inspect the panel, breaker and disconnect for heat damage, loose lugs and correct breaker size. The tech compares breaker size against the MOCP (maximum overcurrent protection) and MCA on the Goodman rating plate.
  3. Test the dual run capacitor with a capacitance meter against its µF rating. Tolerance is typically ±6%.
  4. Megohm or ohm test the compressor windings. The tech tests common, start and run terminals to each other and to ground to rule out a grounded or open compressor.
  5. Test the condenser fan motor for winding shorts to ground and check whether it spins freely.
  6. Inspect the contactor for pitting, welding or a burnt coil, and check all wiring and terminals.
  7. Measure voltage and amperage during startup and running. The tech compares readings to the nameplate RLA and LRA. Low supply voltage or locked-rotor draw on a hard start is a key finding.
  8. On the indoor side, check heat strip element resistance, sequencers or relays, and the blower motor. The tech also confirms the heat kit matches the air handler and breaker.
  9. On communicating models, read stored fault codes on the control board or thermostat.

On inverter-driven variable-speed models, steps 3 and 6 do not apply because there is no compressor run capacitor or conventional contactor. The tech will instead focus on the inverter drive and its components and the ECM fan motor, along with the panel, wiring, indoor-side and fault-code checks above.

A quote should name the specific failed component and the measurement that proved it. Be wary of “you need a new compressor” or “a new system” without winding test results. A hard-starting compressor may also warrant a hard-start kit, but that should be a deliberate recommendation, not a guess.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Outdoor breaker trips the instant it’s resetGrounded compressor, shorted wiring or fan motorLeave breaker off; call a proMegohm/ohm test windings, inspect wiring, isolate short
Breaker trips a few seconds after outdoor unit tries to start, often with a humWeak capacitor or hard-starting compressorReset once after 5 minutes off; if it repeats, leave offTest and replace capacitor; consider hard-start kit; check voltage
Breaker trips after running 10+ minutesFailing fan motor, dirty coil, loose connection, worn breakerClear debris around unit, replace filterAmp-draw test, motor test, tighten or repair terminals, test breaker
Indoor breaker trips only in cold weather or when aux heat runsShorted heat strip, failed sequencer, undersized circuitConfirm not stuck on Emergency Heat; replace filterTest elements and sequencers, verify heat kit and breaker sizing
Smoke, sparking, or persistent burning odorArcing or overheating at contactor, lugs or wiringKeep power off at the panel; move away; call 911 if any sign of fireReplace damaged wiring, contactor or breaker; inspect for heat damage
Buzzing or scorch marks at unit or panelArcing at contactor, lugs or wiringKeep power off; do not resetReplace damaged wiring, contactor or breaker; inspect for heat damage
Breaker trips with no other symptoms on an older panelBreaker worn or undersizedNote breaker size and age for the techVerify against MOCP, replace breaker if faulty

Goodman heat pump breaker keeps tripping repair cost

Typical US ranges, including parts and labor:

RepairTypical cost
Service call / diagnostic$75 – $200
Dual run capacitor replacement$120 – $350
Contactor replacement$150 – $350
Hard-start kit installed$150 – $400
Wiring or terminal repair$100 – $400
Circuit breaker replacement$150 – $350 (more for uncommon panels)
Condenser fan motor replacement$300 – $700
Heat strip element or sequencer/relay$200 – $600
Compressor replacement$1,800 – $3,500+
Full outdoor unit replacement$3,500 – $7,500+

Goodman’s parts warranty is 10 years on registered units, and some models carry a lifetime compressor warranty. Coverage depends on your specific model and whether it was registered, so don’t assume a lifetime compressor warranty applies to your unit. Before approving compressor work, verify your model’s registered warranty terms with Goodman or your installer. Warranty often covers the part but not the labor. If the compressor is grounded on an older unit, ask for a repair-versus-replace comparison.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Frequently asked questions

Can I just keep resetting the breaker on my Goodman heat pump?

No. Reset it once. If it trips again, leave it off and call a technician. A breaker that trips repeatedly is reporting a real overcurrent or short circuit. Forcing it back on can overheat wiring, damage the compressor, or create a fire risk.

Which breaker is tripping, and does it matter?

Yes. Most Goodman heat pumps have one 240V breaker for the outdoor unit and a separate breaker, or two, for the indoor air handler and its electric heat strips. An outdoor breaker trip points to the compressor, capacitor, fan or outdoor wiring. An indoor breaker trip in cold weather often points to the heat strips or blower.

Does the breaker trip mean my compressor is dead?

Not necessarily. On capacitor-run models, a weak capacitor, failing contactor, shorted fan motor, or loose or corroded wiring is more common and far cheaper to fix. A technician has to test the compressor windings to rule out a grounded or shorted compressor.

Is it the breaker itself that's bad?

Sometimes. Breakers wear out and can trip below their rated current, especially older ones or ones that have tripped many times. An electrician or HVAC tech can measure the unit's running amps and compare them to the breaker rating before replacing it.

Will a Goodman heat pump reset itself after a breaker trip?

The breaker never resets itself. You have to switch it back on manually. Once power returns, the unit will try to restart on the next thermostat call, after any built-in compressor delay on models with a timer or communicating control.

Does this apply to my inverter or variable-speed Goodman heat pump?

Only partly. Inverter-driven variable-speed models drive the compressor through an inverter board and typically use an ECM fan, so they have no compressor run capacitor or conventional contactor. On those units, breaker trips point to the inverter drive, its components, or the ECM motor. The homeowner safe checks still apply, but the cause list and diagnosis on this page do not.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.