Goodman Heat Pump Compressor Not Running: Causes & Costs

Last updated Oct 13, 2026 · By fixme.vip Editorial

Goodman Heat Pump: Compressor not running
Applies to: Goodman split heat pumps (GSZ, GSZC, GSZB, DSZC, SSZ series and older CPKJ/CHP models). Single-stage units use a defrost control board with an optional high/low pressure switch lockout. ComfortBridge and communicating variable-speed models (GSZC7, DSZC) report faults through the outdoor board and thermostat. Diagnostic LED codes and lockout behavior differ by board revision.
Typical repair cost: $0 DIY – $150-$450 for a capacitor or contactor, $1,800–$4,000+ if the compressor needs replacement — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Goodman heat pump compressor not running: what it means

“Compressor not running” is a symptom, not a single flash code. The thermostat is calling, and the indoor blower may run. At the outdoor unit, the compressor is silent. The fan may or may not be turning.

On Goodman heat pumps, the compressor is switched by a contactor. That contactor is controlled by the defrost control board and the thermostat’s Y signal.

Several things can block that path:

Whether it resets on its own depends on the cause:

If your outdoor fan is also dead, see the related fan page. If the breaker trips, see the breaker page.

Goodman heat pump compressor not running: common causes, ranked by probability

  1. Failed run capacitor (dual capacitor). This is the most common cause on Goodman units. The compressor hums or clicks on its overload but won’t start. The fan may still spin.
  2. Bad or pitted contactor. Burned contacts or a failed coil mean no voltage reaches the compressor. Insects or debris between the contacts are also common.
  3. Compressor internal thermal overload open. The compressor is too hot. This is often caused by low refrigerant charge, a dirty outdoor coil, or a weak capacitor. It resets once cooled.
  4. High or low pressure switch tripped / board lockout. Typical causes:
    • Low charge from a leak (low-pressure switch)
    • A blocked coil or failed outdoor fan (high-pressure switch)
  5. No 24V call reaching the outdoor unit. Possible reasons:
    • Thermostat setting or dead batteries
    • Broken low-voltage wire
    • Blown 3A fuse on the indoor board
    • Tripped float switch
  6. Defrost control board fault. The board fails to energize the contactor, or it’s stuck in a delay or lockout.
  7. Seized compressor or open/shorted windings. This is the least common cause but the most expensive. It is sometimes helped temporarily by a hard-start kit.

How to fix Goodman heat pump compressor not running: safe checks first

Don’t touch anything inside the outdoor cabinet. Capacitors hold a dangerous charge even with the power off.

How a technician will diagnose it

A credible quote names the specific failed part and the test result behind it, for example “capacitor reads 28 µF on a 45 µF rating.” Be cautious of a compressor replacement quote that has no winding or amp test behind it.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Outdoor unit hums, then clicks offFailed capacitor or seized compressorTurn the system off at the thermostatTest and replace the capacitor; test windings; consider a hard-start kit
Fan runs, compressor silentBad capacitor section or overload openTurn off and let it rest 1 hourTest the capacitor and windings, and check the charge
Nothing runs outside, indoor blower runsNo 24V call, contactor fault or tripped breakerCheck thermostat, batteries, breaker and disconnectCheck 24V, the contactor, the indoor fuse and the board
Runs a few minutes, then stops repeatedlyPressure switch trip, low charge or dirty coilReplace the filter and clear around the unitGauge check, leak search, coil cleaning, board lockout reset
Breaker trips when compressor tries to startShorted compressor or grounded wiringReset once onlyMegger or ohm test the compressor and inspect wiring
Water in pan, system deadFloat switch trippedClear the condensate lineVerify the float switch and drain

Goodman heat pump compressor not running repair cost

RepairTypical US cost (installed)
Thermostat batteries, filter, breaker reset$0–$40 DIY
Service call / diagnostic$90–$200
Run capacitor (dual)$150–$450
Contactor$150–$400
Hard-start kit$200–$450
Pressure switch$200–$500 (more if refrigerant recovery is needed)
Defrost control board$300–$700
Leak repair plus R-410A or R-454B recharge$400–$1,500+
Compressor replacement (under parts warranty)$1,500–$2,800 (labor and refrigerant)
Compressor replacement (out of warranty)$1,800–$4,000+
New heat pump outdoor unit (often weighed against an old compressor)$4,000–$8,000+
Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why does my Goodman heat pump fan run but the compressor doesn't?

The outdoor fan and the compressor share a contactor but often use separate capacitor sections. A failed dual run capacitor, a seized compressor or a tripped internal overload can stop the compressor while the fan keeps spinning. A technician needs to test the capacitor and the compressor windings.

Will the compressor restart on its own?

Sometimes. The compressor's internal thermal overload resets on its own once the compressor cools down, which can take an hour or more. A high or low pressure switch lockout on Goodman defrost boards usually holds after repeated trips until you cycle power. Cycling power once is fine. Don't keep resetting it.

Is it safe to keep running the heat pump with the compressor off?

In heating mode, backup electric strips may keep the house warm, but your bills will climb quickly. In cooling mode, you only get fan air. Repeated hard-start attempts can overheat the windings, so turn the system off at the thermostat until a technician has looked at it.

Is a non-running compressor covered by Goodman warranty?

Goodman compressors usually carry a 10-year parts limited warranty when the unit was registered on time. Some models carry a lifetime compressor warranty. Labor and refrigerant are usually not covered unless you bought an extended labor plan. Have your model and serial number ready.