Goodman Heat Pump Not Heating: Causes, Fixes & Costs

Last updated Oct 4, 2026 · By fixme.vip Editorial

Goodman Heat Pump: Not heating
Applies to: Goodman split-system heat pumps (GSZ, GSZC, GSZB, DSZC and similar series). Defrost controls, fault-code LEDs and communicating (ComfortNet) features vary by model and board, so check the wiring diagram and installation manual on your outdoor unit.
Typical repair cost: $0 DIY – $2,500+ if the compressor or reversing valve must be replaced — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Goodman heat pump not heating: what it means

“Not heating” is a symptom, not a numbered code. Your Goodman heat pump either does not run in heat mode, runs but delivers cool air, or cannot keep the house at the thermostat setting.

A heat pump makes heat by running refrigerant in reverse through a reversing valve. Because of that, heating faults often trace back to:

Some symptoms are normal and are not faults:

Some Goodman models have a diagnostic LED on the outdoor control board, and communicating systems may show fault codes at the thermostat. Code meanings and whether the unit resets on its own vary by board. Many boards retry automatically after an anti-short-cycle delay, while some lockouts hold until power is cycled.

Severity is “pro” because nearly every real cause sits inside the cabinet or the refrigerant circuit.

Goodman heat pump not heating: common causes, ranked by probability

  1. Thermostat setup or wiring. The thermostat may be in the wrong mode or configured for a conventional system instead of a heat pump. The O/B reversing-valve setting may be wrong, which is common after a thermostat replacement. Goodman heat pumps energize the reversing valve in cooling (O), so a thermostat set to “B” will heat when asked to cool and cool when asked to heat.
  2. Normal defrost or a defrost-system fault. A stuck defrost cycle, failed defrost thermostat or sensor, or defrost control board fault can leave the outdoor coil iced over. An iced coil cannot pull heat from outdoor air.
  3. Restricted airflow. A clogged filter, closed registers or a dirty indoor coil can reduce output and trip high-pressure protection in heat mode.
  4. Low refrigerant charge (leak). The unit runs constantly with weak heat, and the coil may ice unevenly.
  5. Reversing valve or solenoid coil failure. The valve sticks in cooling position, so the unit blows cold air in heat mode even though the compressor runs.
  6. Failed capacitor or contactor. The outdoor fan or compressor will not start, or the unit hums.
  7. Compressor problems. These include tripped internal overload, failed windings or a mechanical failure.
  8. Auxiliary/backup heat not working. In very cold weather a heat pump relies on heat strips. A failed strip, sequencer, or kit breaker, or an incorrect outdoor-temperature lockout setting, leaves the house cold.

How to fix Goodman heat pump not heating: safe checks first

How a technician will diagnose it

A qualified tech should typically:

  1. Verify thermostat configuration and wiring, including O/B, Y, W2 and E.
  2. Confirm 24V calls are reaching the outdoor unit and air handler.
  3. Read any fault LED on the outdoor control board and compare it to the model’s diagnostic chart.
  4. Measure supply-to-return temperature split in heat mode.
  5. Check the contactor, capacitor (µF test) and compressor amperage.
  6. Check the reversing valve:
    • Confirm 24V at the solenoid in cooling.
    • Feel or measure line temperatures to see whether the valve shifts.
  7. Test the defrost sensor or thermostat and the defrost board. Many Goodman boards have test pins to force a defrost.
  8. Connect gauges and check charge using the manufacturer’s heating or charging procedures. A low charge means leak search and repair before recharging.
  9. Inspect heat strips, sequencers or relays, and the strip breakers.

Be wary of a quote that adds refrigerant without a leak check. Also question a compressor or reversing valve replacement quoted without documented electrical and pressure readings.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Cold air in heat mode, outdoor unit runningThermostat O/B setting or reversing valve stuckVerify HEAT mode and heat-pump/O settingTest solenoid coil, replace coil or reversing valve
Outdoor unit iced solidDefrost sensor/board fault, low charge, airflowClear debris; wait one defrost cycle; use EM HEATTest defrost controls, check charge
Fan stops, steam outside, then resumesNormal defrostNoneNone
Outdoor unit silent, indoor fan runsTripped breaker, contactor, capacitor, control faultCheck breaker/disconnect, one resetTest and replace contactor/capacitor, diagnose board
Outdoor unit hums but won’t startCapacitor or compressorShut off power, callCapacitor test/replacement, compressor diagnosis
Runs constantly, weak heatLow refrigerant, dirty filter or coil, very cold weatherReplace filter, open registersLeak search, coil cleaning, charge check
Fine in mild weather, cold below ~30°FBackup heat strips or lockout settingCheck strip breakerTest strips, sequencers, thermostat staging
Whole system shuts off, water in panCondensate float switchClear visible drain lineClean drain/trap, check pump

Goodman heat pump not heating repair cost

Typical US costs including labor:

RepairTypical cost
Thermostat reconfiguration or rewire (service call)$100–$250
New heat-pump thermostat, installed$150–$450
Run capacitor$150–$400
Contactor$150–$350
Defrost sensor or thermostat$150–$350
Defrost control board$300–$700
Reversing valve solenoid coil$150–$400
Reversing valve replacement (brazing, evacuation, recharge)$1,000–$2,500
Leak search and repair, plus R-410A or R-32/R-454B recharge$300–$1,500+ (varies by leak location and refrigerant)
Heat strip element or sequencer$200–$600
Compressor replacement$1,800–$4,000+

Labor coverage varies, so check whether your Goodman parts warranty is still active. Many units carry a 10-year registered parts warranty.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why is my Goodman heat pump blowing cool air in heat mode?

Heat pump air often feels cooler than furnace air, usually 85–100°F at the register. Air that feels truly cold can mean the unit is running in defrost or that the reversing valve or thermostat wiring is keeping it in cooling mode. If the air stays cold after a defrost cycle ends, call a technician.

Is it normal for my heat pump to stop heating and steam outside?

Yes. During defrost, the outdoor fan stops, the unit may steam or whoosh, and the indoor air may feel cool for a few minutes. Goodman defrost cycles normally run for up to about 10 minutes. Constant defrosting, or a unit encased in ice, is not normal.

Does a Goodman heat pump reset itself after a fault?

It depends on the model and control board. Many boards retry automatically after a time delay, but some protective lockouts hold until power is cycled. If a single power reset at the breaker does not restore heat, stop resetting it and call a technician.

Should I use emergency heat if my heat pump stops heating?

Emergency heat (EM HEAT) runs only the backup electric strips or furnace, so it can keep the house warm while you wait for service. It costs much more to run than the heat pump, so use it only as a temporary measure.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.