Goodman Heat Pump Runs Constantly: Causes, Fixes & Costs

Last updated Oct 19, 2026 · By fixme.vip Editorial

Goodman Heat Pump: Runs constantly
Applies to: Goodman split heat pumps (GSZ, GSZB, GSZC, GSZV9, DSZC, SSZ series) with standard 24V thermostats or communicating controls. ComfortBridge communicating systems apply to specific models (for example, GSZC18 and DSZC18), and their diagnostics are read through the CoolCloud app or the outdoor control board's display. Single-stage, two-stage and variable-speed units behave differently, and long run times are normal on two-stage and inverter models.
Typical repair cost: $0 DIY – $150–$450 for a contactor or charge check – $1,200–$3,500 for major parts such as a coil or compressor — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Goodman heat pump runs constantly: what it means

“Runs constantly” is a symptom, not a fault code. Goodman heat pumps do not flash a dedicated code for long run times.

It shows up in one of two forms, and they have different causes:

Model behavior varies:

There is no lockout to reset for this symptom.

If the problem is mainly heat-strip use, see the related page Goodman Heat Pump Aux Heat On Constantly.

Goodman heat pump runs constantly: common causes, ranked by probability

  1. Thermostat setting or setup.
    • The fan is set to ON instead of AUTO. The blower runs nonstop, but the compressor does not.
    • The setpoint is unrealistic.
    • The thermostat is configured with the wrong heat pump settings (O/B reversing valve setting).
  2. Outdoor temperature beyond the balance point. In deep cold or extreme heat, a correctly sized heat pump may run continuously. This is normal, not a fault.
  3. Dirty air filter or restricted airflow. Low airflow cuts capacity, so the unit runs longer to keep up. Closed registers do the same.
  4. Dirty outdoor or indoor coil. Dirt, cottonwood or grass clippings on the outdoor coil, or a dirty evaporator coil indoors, reduce heat transfer.
  5. Low refrigerant charge from a leak. Goodman coils, including some aluminum evaporator coils, can develop leaks. Typical signs are reduced capacity and long run times.
  6. Stuck-closed (welded) contactor. The outdoor unit keeps running even with no call from the thermostat. This is common on older units.
  7. Shorted or damaged thermostat wiring. A short between R and Y (for example, from wire chewed or cut near the outdoor unit) keeps the compressor energized.
  8. Duct leaks or poor insulation. Conditioned air is lost to the attic or crawlspace.
  9. Reversing valve not fully shifting, or a weak compressor. These reduce capacity. They are less common and are technician diagnoses.
  10. Undersized equipment. If the unit has always run nonstop, a load calculation (Manual J) may show the system is too small for the house.

How to fix Goodman heat pump runs constantly: safe checks first

How a technician will diagnose it

A technician will typically work through these checks:

Be wary of a quote that recommends “topping off” refrigerant without mentioning a leak search. Also be wary of replacing the system before airflow and charge have been verified.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Blower runs nonstop, outdoor unit cycles normallyFan set to ONSet the fan to AUTONone needed
Outdoor unit runs with the thermostat OFFWelded contactor or shorted wireShut off the outdoor disconnect or breakerReplace the contactor; repair the wiring
Runs nonstop and never reaches setpoint, weak airflowDirty filter or blocked returnsReplace the filter; open registersCheck static pressure and blower setup; clean the evaporator coil
Runs nonstop, outdoor coil visibly dirtyFouled condenser coilClear debris; in above-freezing weather only, gently hose off from outside, power offChemical coil cleaning
Runs nonstop in cooling mode, warm air from vents, ice on the refrigerant lineLow refrigerant from a leakTurn off the system if ice formsLeak search, repair and charge
Runs nonstop in heating mode, cool air from ventsLow refrigerant from a leakCall a technician (frost on the outdoor coil between defrosts is normal in heating; see Goodman Heat Pump Ice on Outdoor Unit)Leak search, repair and charge
Runs nonstop only in extreme cold or heat, house comfortableNormal capacity limitAccept it, or lower or raise the setpoint slightlyNothing, unless the home can’t hold temperature
Runs nonstop, some rooms hot or coldDuct leaks or poor insulationCheck that visible registers are openSeal and insulate ducts
Always ran nonstop since installationUndersized systemNoneManual J load calculation; equipment review
Runs nonstop with low output in one mode onlyReversing valve problemNoneDiagnose and replace the valve

Goodman heat pump runs constantly repair cost

These are typical US ranges, installed, including labor:

ItemTypical cost
Filter, thermostat settings, battery replacement$0–$40
Service call or diagnostic$90–$200
Contactor replacement$150–$350
Thermostat wiring repair$120–$300
New heat-pump-compatible thermostat, installed$150–$450
Coil cleaning, outdoor and/or indoor$100–$400
Leak search$200–$500
Refrigerant recharge, R-410A (older units) or R-32 (2025+ units)$200–$800, depending on pounds needed; pricing varies by refrigerant
Evaporator coil replacement$1,200–$2,800 (parts may be covered under Goodman’s 10-year parts warranty if the unit was registered)
Reversing valve replacement$900–$2,000
Compressor replacement$1,800–$3,500
Duct sealing$300–$2,000+

Check your warranty before approving major parts. Goodman parts warranties typically require online registration within 60 days of installation. Labor is usually not covered.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Is it normal for a Goodman heat pump to run constantly in very cold weather?

Often, yes. Heat pumps lose capacity as outdoor temperatures drop. Below about 25–35°F, many single-stage units run almost nonstop to hold the setpoint, with auxiliary heat helping. If the house holds temperature, long run times alone are not a fault.

My Goodman runs constantly and the house is comfortable. Is something wrong?

Probably not if you have a two-stage or variable-speed model such as the GSZC or DSZC. Those units are designed to run long and slow at low capacity. On a single-stage unit in mild weather, nonstop running is worth a technician check.

The outdoor unit keeps running even with the thermostat off. What does that mean?

That usually points to a contactor stuck closed or a shorted thermostat wire. The compressor can run with no call and may overheat or freeze the coil. Turn the system off at the outdoor disconnect or breaker and call a technician.

Can low refrigerant make a Goodman heat pump run all the time?

Yes. A low charge, which always means a leak, cuts capacity so the unit can't satisfy the thermostat. A technician has to find and repair the leak and then charge by weight or superheat/subcooling. Adding refrigerant without fixing the leak only buys time.

Does a constantly running heat pump raise my electric bill?

It can, especially if auxiliary electric strips are also running. A unit that runs because of a fault, such as a dirty coil, low charge or stuck contactor, wastes energy and adds wear. Fixing the cause usually lowers the bill noticeably.