Applies to: Lennox communicating (iComfort-enabled) furnaces whose unit controller and matching communicating thermostat display alphanumeric alert codes such as E113. Older non-communicating Lennox furnaces with integrated control boards report faults as LED flash patterns instead of E-numbers; voltage thresholds and reset behavior vary by control.
Typical repair cost: $0 DIY – $900 if utility or panel work is required — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Lennox furnace code E113: what it means

Code E113 on a Lennox furnace means the unit control has detected high line voltage — the incoming 115/120VAC power supply is measuring above the acceptable range the control is designed to run on.

The control watches its supply voltage as a self-protection feature. When voltage climbs too high, the furnace holds operation rather than risk damaging the control board, blower motor, inducer, transformer and other electronics that are sensitive to overvoltage.

Which systems show “E113.” Alphanumeric alert codes like E113 are displayed by Lennox communicating (iComfort-enabled) furnaces — the unit controller and the matching communicating thermostat report them as E-codes. If your furnace is an older, non-communicating model, the control board signals faults with LED flash patterns rather than E-numbers, so a supply-voltage problem on that equipment will show up as a flash code (or simply as a furnace that won’t start) — not as “E113.” Read the diagnostic legend printed inside the blower door or on the control to translate what your specific unit is showing.

This is a supply-side / electrical code. It is not caused by ignition, flame-sensing or gas-supply problems. Lennox uses separate codes for low line voltage, polarity/grounding, and ignition faults — check your unit’s legend to identify those. E113 is specifically about the quality of the power reaching the furnace.

Auto-reset behavior is not consistent across Lennox controls. Some controls will drop the code once voltage returns to range; others hold until power is cycled. Don’t assume either behavior — the diagnostic legend for your unit governs, and exact voltage thresholds differ between controls as well.

Lennox furnace code E113: common causes, ranked by probability

  1. Utility overvoltage — the power company is delivering voltage above nominal (a sustained high reading at the meter). This is the most common genuine cause and is outside your home.
  2. Neutral or service problems at the panel — a loose, corroded or failing neutral connection can cause voltage on one leg to swing high. This is a serious electrical fault requiring an electrician.
  3. Recent electrical work or panel changes — miswiring after service upgrades, generator/transfer-switch installs, or solar interconnections can push furnace voltage out of range.
  4. Board sensing fault — the control itself misreads voltage. A technician confirms this by comparing the control’s reading against an actual meter measurement. A code that is on constantly while no other appliance or light in the house misbehaves most often points here rather than to the supply, because a real sustained overvoltage usually causes symptoms elsewhere in the home.
  5. Transient spikes near measurement — nearby large loads cycling off, or storm-related surges, can momentarily register high voltage and set the code. This fits an intermittent code better than a constant one.

How to fix Lennox furnace code E113: safe checks first

These are the only steps a homeowner should do:

Do not open the furnace cabinet, test voltage yourself, or repeatedly reset the unit. High-voltage electrical work is not a DIY job.

How a technician will diagnose it

A qualified technician or electrician will typically:

If they find the voltage is genuinely in range but the code persists, they’ll investigate the control board.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
E113 with lights dimming/brightening in homeUtility overvoltage or service issueReport to utility; note timesMeasure voltage at meter, coordinate with utility
E113 after recent panel/electrical workMiswiring or loose neutralNone — leave furnace offInspect and correct panel/neutral connections
E113 clears then returns intermittentlyTransient spikes or fluctuating supplyNote patternData-log voltage, test service under load
E113 constant, no other appliance issuesControl sensing fault possibleOne breaker reset only, then leave offCompare control reading vs. meter, replace board if faulty
E113 after generator/solar installInterconnection voltage out of rangeNoneVerify transfer switch/inverter settings

Lennox furnace code E113 repair cost

Honest US ranges — your situation may differ:

Overvoltage caused by the utility is usually corrected at no charge to you, but confirm the source before authorizing internal repairs.

Lennox uses separate alert codes for other electrical and ignition-side conditions — including low line voltage, polarity and grounding problems, and ignition or flame-sensing faults. The numbering differs between communicating controls and flash-code boards, so check the diagnostic legend printed on your unit (inside the blower door or on the control) or the literature for your specific model rather than assuming a neighboring number means a related fault.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Frequently asked questions

Is it safe to keep running my furnace with Code E113?

No. High line voltage can damage the control board, blower motor and other components. The furnace protects itself by holding, and you should have the supply voltage checked before resuming normal use.

Can I fix Code E113 myself?

Usually not. E113 points to the incoming power supply, which involves your electrical panel or utility service. You can reset the breaker once and check the thermostat, but voltage diagnosis is technician or electrician work.

Will Code E113 clear on its own?

Reset behavior is not consistent across Lennox controls, so don't count on it either way — the diagnostic legend for your specific unit governs. Even if the code does clear, persistent or repeated high voltage means the underlying supply problem still needs to be found and corrected.

Who do I call for a high line voltage problem?

Start with your HVAC technician to confirm the reading. If the high voltage is coming from the service or panel, they will refer you to a licensed electrician or your utility company.

Different code on your furnace? Look it up — and if we haven't covered it yet, telling us is how it gets written next.