Lennox Furnace Code E115: Low 24 VAC Causes & Fixes

Last updated Sep 22, 2026 · By fixme.vip Editorial

Lennox Furnace: Code E115
Applies to: Lennox furnaces with SureLight and similar integrated control boards; exact code legend can vary by board revision, so confirm against the label inside the blower door.
Typical repair cost: $0 DIY reset – $1,200+ at the high end if a confirmed-faulty control board has to be replaced; most E115 repairs land far lower — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Lennox furnace code E115: what it means

Lennox Code E115 indicates low 24 VAC at the furnace control board — the low-voltage power that runs the thermostat, relays, gas valve and safety switches has dropped below the level the board needs to operate reliably.

The two documented fault categories are an overloaded (or failing) transformer and a low-voltage wiring problem. The 24-volt “control circuit” is fed by, but separate from, the 120 V line power supplying the furnace — line-side problems are flagged by their own codes, such as E110 and E111. When the control voltage itself sags, the board flags E115 rather than trying to run with unreliable power.

On most Lennox integrated control boards, E115 clears automatically once healthy 24 VAC is restored. If the underlying fault comes and goes, the code will keep reappearing. Because the legend can differ slightly between board revisions, always confirm the code against the diagnostic label inside the blower compartment door.

Lennox furnace code E115: common causes, ranked by probability

  1. Overloaded transformer — too much load on the 24 VAC circuit (added accessories, a stuck relay, or a component drawing more current than the transformer can supply) pulls the voltage down.
  2. Failing transformer — an aging or partially shorted transformer that can no longer hold 24 VAC under load.
  3. Shorted or grounded low-voltage wiring — a pinched, chafed or rodent-damaged thermostat or accessory wire creating a partial short.
  4. Loose or corroded low-voltage connections — poor terminations at the board, thermostat, or accessories causing voltage drop.
  5. A faulty 24 VAC accessory — humidifier, EAC (electronic air cleaner), or zoning panel drawing excess current or shorting the control circuit.

How to fix Lennox furnace code E115: safe checks first

These are the only steps a homeowner should attempt:

Do not open the cabinet, test wiring, or touch the transformer — all of that is technician work.

How a technician will diagnose it

A qualified tech will:

  1. Measure the 24 VAC output at the transformer and at the board terminals under load with a multimeter, comparing readings to spec.
  2. Isolate accessories (humidifier, EAC, zone panel) one at a time to see if removing a load restores normal voltage — this pinpoints an overloaded circuit.
  3. Inspect low-voltage wiring end to end for shorts, pinch points, corrosion, and loose terminations at the board, thermostat, and any accessories.
  4. Check the transformer for overheating or internal short, and confirm its VA rating is adequate for the total connected load.
  5. Verify the control-circuit fuse (if fitted) and confirm the board is receiving and passing proper voltage.
  6. Re-power and confirm E115 clears and stays clear under a full heating cycle.

If a quote jumps straight to a new control board without any voltage or wiring measurements, ask for the readings that justify it.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
E115 with dim/dead thermostatLow 24 VAC / dead batteriesReplace thermostat batteries; single power cycleMeasure transformer output; trace low-voltage supply
E115 returns after resetOverloaded or failing transformerStop resetting; call a proLoad-test and replace transformer; verify VA rating
E115 started after adding humidifier/air cleanerAccessory overloading 24 VACNoneIsolate accessory; add/replace transformer if needed
E115 intermittent, comes and goesLoose or chafed low-voltage wireNoneInspect and repair wiring and terminations
E115 plus furnace won’t run at allShorted control circuitConfirm breaker/switch onLocate and clear short; repair damaged wire

Lennox furnace code E115 repair cost

Honest US ranges (parts + labor; regional variation applies):

Most E115 calls resolve on the lower end — a transformer or wiring fix — rather than a full board swap.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Frequently asked questions

Can I fix Lennox Code E115 myself?

You can cycle power once and confirm your thermostat, breaker and filter are fine, but transformer and wiring work belongs to a licensed technician.

Does Code E115 reset on its own?

On most Lennox boards E115 clears automatically once stable 24 VAC returns, but if the fault repeats it will keep re-flashing until the cause is fixed.

What causes low 24 VAC on a Lennox furnace?

A failing or overloaded transformer, a shorted accessory, or a pinched or corroded low-voltage wire are the documented triggers for this code.

Is it safe to keep running the furnace with Code E115?

No. Low control voltage can cause erratic operation and further component damage, so have it diagnosed before relying on the system.

Different code on your furnace? Look it up — and if we haven't covered it yet, telling us is how it gets written next.