Lennox · Heat Pump

Lennox Heat Pump Aux Heat On Constantly: Causes & Fixes

Last updated Oct 9, 2026 · By fixme.vip Editorial

Lennox Heat Pump: Auxiliary heat on constantly
Applies to: Lennox split heat pumps (XP, EL, ML, SL series) with electric air handler heat strips or dual-fuel furnace backup. Behavior depends on the thermostat (iComfort, ComfortSense or third-party), outdoor control board and lockout settings. Dual-fuel systems use the furnace as backup instead of strips.
Typical repair cost: $0 DIY – $1,500+ if a refrigerant leak must be found and repaired — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Lennox heat pump auxiliary heat on constantly: what it means

“Auxiliary heat on constantly” is a symptom, not a fault code. Your Lennox thermostat or control is calling for backup heat almost all the time. That backup is either electric heat strips in the air handler or, on dual-fuel systems, the gas furnace.

Lennox systems bring on aux heat (the W1/W2 call) in a few situations:

Several things change how this looks on your system:

Nothing latches or holds a code. Aux heat keeps running for as long as the condition causing it continues.

This page covers aux heat running while the heat pump is running. If the heat pump isn’t producing heat at all, see Lennox Heat Pump Not Heating. If the outdoor coil is iced, see the frozen and ice-related pages listed under Related codes.

Lennox heat pump auxiliary heat on constantly: common causes, ranked by probability

  1. Thermostat is set to Emergency Heat, or set up wrong. Common setup errors include:

    • Wrong system type or equipment type.
    • Missing or wrong outdoor temperature lockout / balance point.
    • The aux “droop” or timer is set too aggressively.
    • On dual-fuel systems, the changeover temperature is set too high.

    This is especially common after a thermostat replacement.

  2. Large setpoint jumps or deep night setbacks. Raising the temperature 3°F or more, or recovering from a setback, triggers aux heat on many thermostats. Lennox smart thermostats limit this with “smart recovery,” but other thermostats may not.

  3. Restricted airflow. A dirty filter, closed registers or a dirty indoor coil reduce heat pump output. The thermostat then calls for backup heat.

  4. Low refrigerant charge (leak). The heat pump runs but delivers lukewarm air, so the thermostat keeps calling aux. This is very common on older units.

  5. Reversing valve problem. If the valve is stuck partly in cooling position or leaking through, heating capacity drops.

  6. Outdoor unit not running, or running weakly. Possible causes include:

    • A failed capacitor or contactor.
    • A failed outdoor fan motor.
    • A compressor fault.

    In this case the “heat” you feel is almost all from aux.

  7. Defrost problems. A faulty defrost thermostat/sensor or outdoor control board can repeat defrost cycles or leave the coil iced, which runs aux heat during each defrost. Covered in detail on the defrost-related pages.

  8. Wiring or relay fault. Possible causes include:

    • A shorted or miswired W/E terminal.
    • A stuck heat-strip sequencer or relay in the air handler.
    • A fault on the dual-fuel control.

    When a relay or sequencer is stuck, the strips can stay energized even with no call. Sometimes they run even with the thermostat off.

  9. Undersized system or extreme cold. Below the heat pump’s balance point, which is often in the 20s–30s°F, long aux run times are normal. This is not a fault.

How to fix Lennox heat pump auxiliary heat on constantly: safe checks first

If the heat strips seem to run with the thermostat OFF, turn the system off at the breaker and call a technician. A stuck relay can overheat the air handler.

How a technician will diagnose it

A competent technician will typically:

  1. Check the thermostat. They should review its setup, wiring (O/B, Y, W1/W2, E, outdoor sensor) and lockout/balance-point settings. On iComfort systems they’ll check the equipment configuration and any stored alerts.
  2. Watch the system run in HEAT only, with aux disabled or locked out. They’ll check whether the outdoor unit is running. They’ll measure supply and return air temperatures. A heat pump in mild weather usually produces a 20°F rise or more.
  3. Check airflow. This includes static pressure, the indoor coil and blower speed settings.
  4. Check refrigerant performance. They’ll connect gauges and check pressures, superheat and subcooling against the Lennox charging chart. A low charge leads to a leak search; Lennox recommends leak repair, not just a top-off.
  5. Test the reversing valve. They’ll check its operation and the solenoid coil, and use temperature checks for internal bypass.
  6. Electrically test outdoor components. This covers the capacitor, contactor and fan motor, plus compressor amperage.
  7. Check defrost operation. This covers the defrost sensor and the board’s defrost settings and timing.
  8. Check the heat strips. They’ll confirm the sequencers or relays open when the W call ends. They’ll also check strip amperage and the dual-fuel control logic.

A quote that says only “add refrigerant” without a leak check, or “replace the heat pump” without measurements, deserves a second opinion.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Display shows EM or Emergency HeatThermostat in emergency modeSwitch to HEATNone if that fixes it
Aux comes on after each setpoint change or in the morningSetback recovery or aggressive droop settingMake smaller changes; reduce setbacksAdjust staging and droop settings
Aux runs often since a new thermostat was installedThermostat configured wrong or miswiredNote settings and photograph the displayCorrect configuration, wiring and lockouts
Weak airflow, dirty filterAirflow restrictionReplace filter; open registersClean coil; check blower and static pressure
Outdoor unit runs, but air is lukewarmLow refrigerant charge or reversing valve problemNone beyond the safe checksLeak search and repair, recharge, valve diagnosis
Outdoor fan or compressor not runningCapacitor, contactor, motor or compressor faultReset breaker onceElectrical testing and part replacement
Outdoor coil iced or constant defrostDefrost sensor or board faultClear snow from around the unit onlyDefrost system diagnosis
Heat strips run even with the thermostat offStuck sequencer or relay, or shorted W wireShut off the breaker and callReplace sequencer/relay; repair wiring
Long aux run times only in very cold weatherBelow balance point (normal)Keep a steady setpointVerify sizing and lockout settings if bills seem excessive

Lennox heat pump auxiliary heat on constantly repair cost

Typical US prices, including labor:

RepairTypical cost
Thermostat setting correction (DIY)$0
Service call / diagnostic$90–$200
Thermostat reconfiguration or rewiring$100–$250
New thermostat$50–$350 for the part, $150–$500 installed
Lennox iComfort thermostat$300–$700+ installed
Air filter$10–$60 (Lennox Healthy Climate media filters at the high end)
Indoor coil cleaning$150–$400
Capacitor$120–$300
Contactor$150–$350
Outdoor fan motor$350–$800
Defrost sensor$150–$350
Outdoor control board$300–$800
Heat-strip sequencer or relay$150–$400
Leak search plus recharge$300–$1,500+ depending on leak location and refrigerant (R-410A, or newer R-454B systems)
Evaporator coil replacement$1,200–$2,800
Reversing valve replacement$900–$2,000 (brazing and refrigerant work)
Compressor replacement$1,800–$3,500+

When the compressor or coil fails on an older unit, many owners weigh full replacement instead.

Check your Lennox warranty before paying for parts. Registered systems often carry a 10-year parts warranty, but labor is usually extra.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Is it normal for aux heat to come on with a Lennox heat pump?

Yes, briefly. Aux heat normally runs during defrost cycles, when you raise the setpoint by a few degrees, and in very cold weather when the heat pump alone can't keep up. If it runs for hours in mild weather (above roughly 35–40°F), something is wrong.

Is aux heat running constantly dangerous?

It's usually not a safety hazard, but it is expensive. Electric heat strips can cost two to three times as much to run as the heat pump. It can also hide a failing compressor or refrigerant leak that gets more costly to fix the longer it goes.

What's the difference between aux heat and emergency heat?

The thermostat turns on aux heat automatically to help the heat pump. You select emergency heat manually, and it shuts the heat pump off so only backup heat runs. If someone left the thermostat in EM HEAT, backup heat will run constantly by design.

Should I switch to emergency heat until the technician arrives?

If the outdoor unit is clearly not running or is iced solid, emergency heat keeps the house warm and stops the heat pump from straining. Expect higher electric bills. Tell the technician you did this.

Does this problem reset itself?

There is no fault code that clears. Aux heat comes on whenever the thermostat or control decides the heat pump can't keep up. It stops when the underlying cause is fixed or the thermostat settings are corrected.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.