Lennox · Heat Pump

Lennox Heat Pump Blowing Cold Air in Heat Mode: Fixes

Last updated Oct 10, 2026 · By fixme.vip Editorial

Lennox Heat Pump: Blowing cold air in heat mode
Applies to: Lennox Merit, Elite and Signature split-system heat pumps with air handlers or furnaces. Defrost board type, iComfort/S30/S40 thermostat behavior, and variable-speed indoor fan logic vary by series.
Typical repair cost: $0 DIY – $2,500+ if a reversing valve or compressor must be replaced — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

Lennox heat pump blowing cold air in heat mode: what it means

“Blowing cold air in heat mode” is a symptom, not a numeric fault code. Lennox heat pumps usually do not display a specific code for it. On some systems, an iComfort or S30/S40 thermostat may log related alerts, such as low-pressure, high-discharge-temperature, or outdoor-unit communication alerts. Alert availability varies by model and thermostat.

The symptom means one of three things:

This page focuses on air that is actively cold, as opposed to running with weak heat. For a system that won’t heat at all, or that leans on aux heat, see the related pages listed below.

Reset behavior:

Lennox heat pump blowing cold air in heat mode: common causes, ranked by probability

  1. Normal defrost cycle or perceived-cool supply air. During defrost, the unit temporarily switches to cooling to melt ice off the outdoor coil. Even in normal heating, heat pump air feels cooler than furnace air.

  2. Thermostat setup issue. Common examples:

    • The thermostat is set to Cool or Fan On.
    • It is configured for a conventional system instead of a heat pump.
    • The O/B reversing-valve setting is wrong. Lennox uses an O (energize-in-cool) reversing valve, so a “B” setting inverts heat and cool.

    This often appears right after a new thermostat install.

  3. Outdoor unit not running while the indoor blower runs. Possible causes:

    • A tripped outdoor breaker or disconnect.
    • A failed capacitor or contactor.
    • The defrost board has locked out the compressor on a pressure switch.
  4. Low refrigerant charge (leak). This reduces heating capacity and can trip the low-pressure switch. Supply air ends up near room temperature or cooler.

  5. Reversing valve stuck or failed. The coil may have failed electrically, or the valve may be mechanically stuck in the cooling position. The system then cools while calling for heat.

  6. Defrost control or sensor fault. A bad defrost board, coil sensor, or ambient sensor can leave the unit stuck in or cycling through defrost. See “Stuck in Defrost Mode” for that case.

  7. Auxiliary/backup heat not working during defrost or in deep cold. Causes include failed heat strips, sequencers, or limits, or a backup heat source that is disabled in the thermostat.

  8. Compressor failure. Examples are a failed winding, an internal overload trip, or a mechanical failure. The fan may run while the compressor does not.

How to fix Lennox heat pump blowing cold air in heat mode: safe checks first

How a technician will diagnose it

A good quote should name the failed component and the measurement that proved it. “Needs Freon” without a leak search, or “reversing valve” without a coil and temperature test, deserves a second opinion.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Cool air for a few minutes, outdoor unit steamingNormal defrostWait 10–15 minNone unless frequent or long
Cold air right after new thermostat installWrong O/B or system type settingVerify Heat mode; note install dateReconfigure thermostat to heat pump, O energized in cool
Indoor fan runs, outdoor unit silentTripped breaker, capacitor/contactor, pressure lockoutCheck breakers; one resetTest capacitor/contactor; read board fault LEDs
Outdoor unit runs, air cool, ice pattern oddLow refrigerant chargeReplace filter; callGauge check, leak search, repair and recharge
House getting colder, air cold like ACReversing valve stuck in coolSwitch to Emergency HeatTest solenoid coil; replace coil or valve
Cycles into defrost repeatedly or won’t exitDefrost board/sensor faultClear snow around unitTest sensors; replace defrost board
Air cold in deep cold or during defrostAux heat failureCheck air handler breakerTest heat strips, sequencers, limits
Outdoor fan runs, compressor doesn’t, hummingCompressor or start component failureTurn system off; callAmp draw/winding tests; repair or replace

Lennox heat pump blowing cold air in heat mode repair cost

Typical US ranges, including labor:

RepairCost
Thermostat reconfiguration$90–$200 (service call)
Run capacitor$150–$400
Contactor$150–$350
Defrost control board$300–$700 (communicating iComfort outdoor control boards on Signature-series units can cost more)
Defrost/coil sensor$150–$350
Refrigerant leak search and recharge$400–$1,500+ (R-410A vs R-454B pricing varies; larger leak repairs or coil replacement cost more)
Reversing valve solenoid coil only$200–$450
Reversing valve replacement$1,000–$2,500
Heat strip element or sequencer$200–$600
Compressor replacement$1,800–$4,000+

Warranty notes:

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Is it normal for my Lennox heat pump to blow cool air sometimes?

Yes, briefly. Heat pump supply air is often only 85–95°F, which feels cool on your hand compared with a furnace. During a defrost cycle (usually a few minutes), air can also feel cool unless auxiliary heat tempers it. Steady cold air that lasts longer than about 10–15 minutes is not normal.

Why does my Lennox heat pump blow cold air only in very cold weather?

As outdoor temperatures fall, a standard heat pump's output and supply air temperature drop. If auxiliary or backup heat isn't wired, enabled, or working, the air can feel lukewarm or cool. A technician can confirm the aux heat strips or the furnace backup are being called and are working.

Can I fix a stuck reversing valve myself?

No. Diagnosing the reversing valve requires checking coil voltage and refrigerant line temperatures, and replacing it means recovering refrigerant and brazing. That work requires EPA certification. Your part is limited to confirming thermostat settings, the filter, and the breakers.

Should I keep running the system if it's blowing cold air?

No. If you have backup heat, switch the thermostat to Emergency Heat. If you don't, turn the system off at the thermostat. Then call a technician. Leaving the heat pump running while it blows cold air can mean it is cooling the house or is low on refrigerant, and continued running can damage the compressor.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.