York Heat Pump Aux Heat On Constantly: Causes & Fixes

Last updated Oct 9, 2026 · By fixme.vip Editorial

York Heat Pump: Auxiliary heat on constantly
Applies to: York and Johnson Controls split heat pumps (e.g. YZ, YH, YHE series) paired with York or Coleman air handlers or furnaces (dual fuel). How aux heat is staged depends on the thermostat (York Hx, Affinity/Touch, or third-party), the air handler heat-kit control, and the outdoor unit control board. Behavior varies by model and installation.
Typical repair cost: $0 DIY thermostat fix – $1,500+ if a refrigerant leak must be found and repaired — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

York heat pump auxiliary heat on constantly: what it means

“Auxiliary heat on constantly” is not a York flash code. It means the thermostat or control is calling for second-stage backup heat (electric strips, or a gas furnace on dual-fuel systems) almost all the time. You may also see an “AUX” or “AUX HEAT” indicator stay lit.

A York heat pump normally adds aux heat in three situations:

If aux runs constantly, there are two broad possibilities:

The second case overlaps with “Not heating” and “Frozen and not defrosting.” This page focuses on how to tell which situation you’re in, and on the aux-specific causes.

York heat pump auxiliary heat on constantly: common causes, ranked by probability

  1. Thermostat set to Emergency Heat (EM HEAT). This locks out the compressor so only backup heat runs.
  2. Thermostat configuration. Common problems include:
    • The thermostat is set up as a gas/electric system instead of a heat pump.
    • Aux heat lockout or balance-point settings are missing or wrong.
    • Recovery or “smart recovery” settings bring on aux after every setback.
    • Large manual setpoint jumps of 2-3°F or more trigger aux.
  3. Heat pump not producing heat. The compressor or outdoor fan isn’t running, there’s a failed capacitor or contactor, or the reversing valve is stuck. The thermostat then falls back on aux.
  4. Low refrigerant charge from a leak. The heat pump runs, but its output is weak.
  5. Outdoor coil iced over or stuck in defrost. Defrost energizes aux by design. See “Stuck in defrost mode.”
  6. Wiring or control fault. Examples include a W2/E wire miswired or shorted, a heat-kit sequencer or relay welded closed, or an outdoor thermostat or dual-fuel control that has failed. In this case the strips can run even when the thermostat shows no aux call.
  7. Restricted airflow. A dirty filter or closed registers reduce heat-pump output and can cause high-pressure trips.
  8. Undersized system or very cold weather. Some aux use below the balance point (often 25-35°F) is expected, not a fault.

How to fix York heat pump auxiliary heat on constantly: safe checks first

How a technician will diagnose it

A sound diagnosis typically includes these steps:

Be cautious about a quote for “add refrigerant” with no leak search, or for a new system before a simple settings check has been done.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
EM HEAT shown, outdoor unit offEmergency heat selectedSwitch to HEATNone
AUX comes on after every schedule changeRecovery or setback settings, large setpoint jumpsUse small steps, hold a steady temperatureAdjust droop and aux lockout settings
AUX on, outdoor unit silentCompressor, capacitor, contactor or breakerCheck and reset the breaker onceElectrical diagnosis and component replacement
Outdoor unit runs, air lukewarm, AUX onLow charge or stuck reversing valveReplace filterFind and repair the leak, recharge, or replace the valve
Heavy ice, AUX on for a long timeDefrost failureVisual check onlyTest the defrost sensor and board
Strips heat with no AUX callWelded sequencer/relay or wiring faultTurn off and callReplace the sequencer or relay, repair wiring
AUX only below about 30°F outdoorsNormal balance-point operationNoneOptional load or balance-point review

York heat pump auxiliary heat on constantly repair cost

RepairTypical US cost
Thermostat settings fix$0 DIY; $90-$200 service call
New thermostat installed$150-$500
Run capacitor$120-$350
Contactor$150-$350
Heat-kit sequencer/relay$150-$400
Defrost sensor or control board$200-$650
Leak search and repair plus recharge$400-$1,500+, depending on leak location and refrigerant
Reversing valve$900-$2,000
Compressor$1,800-$3,500+ (often weighed against replacing the system)
Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Is it normal for aux heat to come on sometimes with a York heat pump?

Yes. Aux heat is meant to help during defrost cycles, after a large setpoint increase, and in very cold weather when the heat pump can't keep up. It is not normal for aux heat to run most of the time in mild weather, roughly above 35-40°F.

What's the difference between aux heat and emergency heat?

Aux heat is added automatically alongside the heat pump. Emergency heat is chosen by you, and it turns the heat pump off so only the backup heat runs. If the thermostat is accidentally left in EM HEAT, the backup heat will run constantly.

Can I keep running it with aux heat on constantly?

Usually yes for a short time, and the house will stay warm. Electric strip heat costs roughly two to three times as much to run as the heat pump. Constant aux can also hide a failed compressor or a refrigerant leak that gets worse. Book service soon.

Will my York system reset this by itself?

There is no single fault code for constant aux heat. It is a symptom, not a lockout. If a setting is the cause, fixing the setting fixes it right away. If the heat pump has failed or is short of capacity, it continues until a technician repairs it. Outdoor board lockout codes vary by model.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.