York · Heat Pump

York Heat Pump Compressor Not Running: Causes & Fixes

Last updated Oct 13, 2026 · By fixme.vip Editorial

York Heat Pump: Compressor not running
Applies to: York and related Johnson Controls split heat pumps (e.g. YZ, YH, YHE, YHJF and Affinity/LX series) with single-stage, two-stage or variable-speed compressors. Control boards, lockout timing, and LED fault codes vary by model and board revision, so check the wiring diagram and fault-code label inside your outdoor unit's control panel.
Typical repair cost: $0 DIY – $150-$450 for a capacitor or contactor, $1,800-$4,500+ for a compressor replacement — compare free local quotes

Get this fixed by a local pro

Free, no-obligation quotes from licensed HVAC technicians in your area. Compare up to 3 estimates before anyone visits.

Get free local quotes

York heat pump compressor not running: what it means

“Compressor not running” is a symptom, not a numbered fault code. It means the outdoor unit is getting a call for heating or cooling, but the compressor isn’t starting. You may notice:

Without the compressor, a York heat pump can’t move heat. In heat mode, the indoor unit falls back on auxiliary or electric strip heat, which costs more to run. In cooling mode, it just blows room-temperature air.

Many York and Johnson Controls outdoor boards protect the compressor with several safeties:

When one of these trips, the board flashes an LED fault code. Codes and lockout behavior vary by board. On many boards, a single pressure trip clears on its own after a delay. Repeated trips within one call for heat or cooling cause a “hard” lockout that holds until power is cycled. The exact meaning is on the label inside your unit’s control panel.

Because the likely causes are electrical parts inside the cabinet or the refrigerant circuit, this is professional-level work.

If you’re seeing these symptoms instead, see the related pages listed at the bottom:

York heat pump compressor not running: common causes, ranked by probability

  1. Failed run capacitor (or the compressor side of a dual capacitor). This is the most common cause. Typical signs are a hum, or the fan running while the compressor stays silent.
  2. Short-cycle delay or thermostat issue. The compressor may simply be waiting out its delay timer. Or the thermostat may be set wrong, have dead batteries, or not be sending a heat/cool call (Y signal) to the unit.
  3. Bad contactor. Pitted or burned contacts, a failed coil, or ants and debris in the contacts can stop power from reaching the compressor.
  4. Pressure-switch or safety lockout. The causes behind the trip differ by direction:
    • High-pressure trips: a dirty outdoor coil, a restricted indoor airflow path (often a clogged filter in heat mode), or a failed outdoor fan.
    • Low-pressure trips: a refrigerant leak, or a frozen coil.
  5. Compressor thermal overload tripped. The compressor overheated, often because of a bad capacitor, low charge, or high head pressure. It won’t restart until it cools down, which can take 30 to 60 minutes or more.
  6. Control board or wiring fault. This includes a failed defrost or control board, loose or burned wires, or a bad low-voltage connection. Variable-speed models can also have inverter or drive faults, which are model-specific and show as their own LED codes.
  7. Failed compressor. Shorted, grounded, or open windings, or a mechanically locked rotor. A hard-start kit is sometimes tried on a compressor that’s slow to start but otherwise healthy. It doesn’t fix a dead one.

How to fix York heat pump compressor not running: safe checks first

Do not open the outdoor unit’s electrical panel. Capacitors hold a dangerous charge even with the power off.

How a technician will diagnose it

A good technician will typically work through these steps. You can use them to sanity-check a quote:

  1. Read the outdoor board’s LED fault code and check the fault history, if the board stores it.
  2. Confirm power and the call for operation: line voltage at the disconnect and contactor, and 24 V on the Y (and, where used, O/B) terminals.
  3. Check the contactor by inspecting it and measuring voltage across the contacts.
  4. Test the capacitor with a meter and compare the reading to its rated microfarad (µF) value, usually within ±6%.
  5. Measure compressor amp draw at startup. Locked-rotor amps with no start means a stuck compressor or a capacitor problem.
  6. Test the compressor windings. They check resistance across the common, start, and run terminals, and check for a short to ground. If the windings read open, they’ll let the compressor cool to rule out a tripped internal overload.
  7. Check the pressure safeties. They test the high- and low-pressure switches for continuity, then connect gauges to check the refrigerant charge, superheat and subcooling, and look for leaks if the charge is low.
  8. Inspect airflow: coil cleanliness, outdoor fan operation, and indoor blower and filter.

Be cautious if a technician condemns the compressor without showing you winding readings and amp-draw readings, or without first replacing a $20–$60 capacitor that tested weak.

Symptom, cause and what to do

SymptomLikely causeDIY actionTechnician job
Outdoor fan runs, compressor silentBad run capacitor or tripped overloadTurn system off, call a proTest and replace the capacitor; check the overload
Unit hums, nothing spins, then clicks offFailed capacitor or locked compressorShut off at the thermostatTest the capacitor and windings; try a hard-start kit if appropriate
Nothing runs outside at allTripped breaker, thermostat, or contactorCheck the thermostat and batteries; reset the breaker onceCheck 24 V, contactor coil, and wiring
Starts briefly, then stops; LED flashingHigh- or low-pressure lockoutReplace filter, clear outdoor unit, do one power resetRead fault code, check charge, find leaks, clean coil
Compressor stops after a short period of runningLow charge, high head pressure, or weak capacitorCheck filter and outdoor clearanceGauge test, superheat and subcooling, amp draw
Only aux or emergency heat comes onThermostat in Emergency Heat, or compressor faultSwitch the thermostat back to normal HEATFull compressor-circuit diagnosis
Breaker trips when compressor tries to startGrounded compressor or shorted wiringDon’t reset more than onceMegohm/ground test, wiring repair, or compressor replacement

York heat pump compressor not running repair cost

Typical US prices, including parts and labor:

RepairTypical cost
Service call / diagnosis$90–$250
Run or dual capacitor replacement$150–$450
Contactor replacement$150–$400
Hard-start kit$200–$450
Pressure switch replacement$200–$500, more if the system must be recovered and recharged
Refrigerant leak repair plus recharge$400–$1,500+ (R-410A and newer refrigerants vary widely)
Outdoor control or defrost board$300–$800
Inverter drive board (variable-speed models)$600–$1,500+
Compressor replacement$1,800–$4,500+

Compressors are often covered by York’s parts warranty, commonly 10 years with registration, but labor and refrigerant are usually extra. On older units, a compressor failure often makes full system replacement the better value. Get a written quote for both options.

Safety first: anything beyond filters, batteries, and visual checks on gas-burning equipment should be handled by a licensed technician. Repeatedly resetting a locked-out unit can mask a dangerous fault. When in doubt, get a pro.

Parts & tools for this fix

As an Amazon Associate, fixme.vip earns from qualifying purchases. Prices and availability are on Amazon.

Frequently asked questions

Why is my York heat pump outdoor fan running but the compressor isn't?

The fan and compressor share the contactor, so if the fan runs, power is reaching the unit. The most common reason the compressor alone won't start is a failed run capacitor (or the compressor side of a dual capacitor). Other possibilities are a tripped internal overload on a hot compressor, or a compressor with a seized or open winding. A technician needs to test these with a meter.

Can I reset my York heat pump if the compressor stops?

Yes, you can do one reset. Turn the thermostat off, switch off the outdoor disconnect and breaker for about five minutes, then restore power and call for heat or cooling. Many York boards hold a pressure or high-temp lockout until power is cycled, and some clear on their own after a timed delay. If the compressor stops again, don't keep resetting it. Repeated lockouts point to a real fault that resets can make worse.

Is a humming outdoor unit with no compressor running dangerous?

It isn't dangerous to you, but it is hard on the equipment. A compressor that hums without starting is usually a failed capacitor or a locked rotor. It draws high current and will trip on its internal overload over and over. Turn the system off at the thermostat and call a technician rather than letting it keep trying.

How long should I wait for the compressor to start after changing the thermostat?

Most York heat pump controls have an anti-short-cycle delay of about 5 minutes, and some boards use a longer delay after a power interruption. Wait at least 5 to 10 minutes before deciding the compressor isn't running.

Different code on your heat pump? Look it up — and if we haven't covered it yet, telling us is how it gets written next.